home *** CD-ROM | disk | FTP | other *** search
/ InfoMagic Standards 1994 January / InfoMagic Standards - January 1994.iso / ccitt / 1992 / r / r103.asc < prev    next >
Text File  |  1991-12-31  |  10KB  |  396 lines

  1.  
  2.  
  3.  
  4.  
  5.  
  6.  
  7. Recommendation R.103(R.1xy)
  8.  
  9.     CODE AND SPEED-DEPENDANT TDM 600 BIT/S SYSTEM FOR USE IN
  10.        POINT-TO-POINT OR BRANCH-LINE MULDEX CONFIGURATIONS
  11.                                 
  12.  
  13.        The CCITT,
  14.  
  15. considering
  16.  
  17.        (a)  that telex subscribers are often geographically located  in  small
  18. groups;
  19.  
  20.        (b)  that TDM multiplexing systems are economical for the transmission of 
  21. large numbers of channels;
  22.  
  23.        (c)  that certain telex switches handle TDM frames in  accordance  with
  24. Series-R Recommendations directly and that frame fill should be optimized;
  25.  
  26.        (d)  that telex switches handle channels at 50 bauds and a 7.5 unit code;
  27.  
  28.        (e)  that a facility for regenerating start-stop signals is used in new 
  29. TELEX networks;
  30.  
  31.        (f)  that the branch-line multiplexing  system  should  be  capable  of
  32. accepting and regenerating all the signals of the TELEX signalling system;
  33.  
  34.        (g) that the minimum signal transfer delay through TDM systems is achieved 
  35. by the transmission of interleaved elements;
  36.  
  37. recommends
  38.  
  39.        that, where branch-line remote or low multiplex capacity TDM systems are 
  40. to be used for telegraphy, the  equipment  shall  comply  with  the  following
  41. standards:
  42.  
  43. 1.     System capacity
  44.  
  45.        The system shall be capable of multiplexing up to 8 channels at        50 
  46. bauds (7.5 bits including a stop element of 1.5 units).
  47.  
  48. 2.     Start-stop channel inputs
  49.  
  50. 2.1    The modulation rate tolerance that shall be accepted on incoming       50 baud 
  51. start-stop signals with a stop element of 1.4 units shall be at least   + 1.4%.
  52.  
  53. 2.2    When receiving characters at 50 bauds having nominally 1.5-unit stop elements, 
  54. the system shall be capable of transmitting without error isolated incoming characters 
  55. that have a 1-unit stop element, occurring at a maximum rate of one per second.
  56.  
  57. 2.3    The minimum interval between start elements of undistorted successive continuous 
  58. characters that may be presented at the channel input when the nominal modulation rate 
  59. is 50 bauds shall be 145 5/6 ms.
  60.  
  61. 2.4    There shall be no restriction on the continuous transmission of all characters 
  62. (including combination No. 32 of International Telegraph Alphabet No. 2) when they are 
  63. presented at the maximum permitted rate.
  64.  
  65. 2.5    The effective net margin on all channel inputs when undistorted  signals  are
  66. received from a transmitter having a nominal character length and rate shall be at least 
  67. 40%.
  68.  
  69.  
  70.  
  71.  
  72.  
  73.  
  74.  
  75.  
  76.  
  77.  
  78.  
  79.  
  80. 2.6    At the nominal modulation rate of 50 bauds, an input character start  element
  81. shall be rejected if it is less than 0.4 units duration and shall be accepted if it is 
  82. more than 0.6 units duration.
  83.  
  84. 2.7    Elements corresponding to start polarity (at the distant multiplexer  output)
  85. shall be inserted in the aggregate stream if the channels are unequipped.
  86.  
  87. 2.8    In the case of an open-circuit line condition at the start-stop channel input, it 
  88. shall be possible to choose to transmit elements corresponding to a steady start or stop 
  89. polarity in the aggregate bit stream, according to the availability polarity selected.
  90.  
  91. 3.     Start-stop channel outputs
  92.  
  93. 3.1    The maximum degree of gross start-stop distortion, produced by the system on a 
  94. start-stop channel, shall be 3% for all modulation rates.
  95.  
  96. 3.2    The maximum difference possible between the mean modulation rate of the channel 
  97. output signals and the nominal modulation rate shall be 0.2%.
  98.  
  99. 3.3    The minimum stop element duration released at the output shall be 1.25 units, 
  100. whatever the distortion, the length of the stop element or the input rate within the 
  101. range specified in 2.1 - 2.4 of this Recommendation of the character recognized at the 
  102. other end, whether this character is  in  accordance  with  this  Recommendation  or
  103. Recommendations R.101, R.102 or R.112 (for a rate of 50 bauds and a 7.5 unit code).
  104.  
  105. 3.4    Within 6 ms of the recognition of one of the failures described in 8.3 and 8.4 or 
  106. carrier loss signalled by the modem, the steady polarity as selected in accordance with 
  107. 2.8 shall be applied to the channel outputs of the TDM system affected.
  108.  
  109. 3.5    The affected terminal shall signal its synchronization status to the  distant
  110. terminal over the signalling channel provided (control channel).
  111.  
  112. 4.     Multiplexing details
  113.  
  114. 4.1    Channel interleaving shall be on a bit-by-bit multiplexing basis.
  115.  
  116. 4.2    Both start and stop elements of each input character shall be transmitted through 
  117. the aggregate.
  118.  
  119. 4.3    The transfer delay shall not exceed 60 ms.
  120.  
  121. 5.     Frame structure
  122.  
  123. 5.1    A unique frame of 12 bits, of duration 20 ms, equivalent to an aggregate signal 
  124. rate of 600 bit/s shall be used, as shown in Table 1/R.1xy:
  125.  
  126.  
  127.                                    TABLE 1/R.1xy
  128.                                           
  129.                                    Frame details
  130.  
  131.  
  132.  
  133.  
  134.  
  135.  
  136.  
  137.  
  138.  
  139.  
  140.  
  141.  
  142.  
  143.  
  144.  
  145.  
  146.  
  147.  
  148.  
  149.  
  150.  
  151.  
  152.  
  153.  
  154.  
  155.  
  156. 5.2    The frame may be considered as a 600 bit/s start/stop character, time slot "12" 
  157. being the start element of polarity A, slots 10 and 11 forming the stop  element  of
  158. polarity Z, as shown in Figure 1/R.1xy.
  159.  
  160.  
  161.  
  162.  
  163.  
  164.  
  165.  
  166.  
  167.  
  168.  
  169.  
  170.  
  171.  
  172.  
  173.  
  174.  
  175.  
  176.  
  177.  
  178.  
  179.                                    FIGURE 1/R.1xy
  180.                                           
  181.                               Branch-line muldex frame
  182.                                           
  183.                                           
  184. 6.     Aggregate signal details
  185.  
  186. 6.1    The aggregate signal rate shall be 600 bit/s. The tolerance on the modulation 
  187. rate of the receive aggregate signals of the TDM system shall be between +2.3% and  - 
  188. 0.5%.
  189.  
  190. 6.2    The effective net margin of the aggregate signal receiver of the TDM system shall 
  191. be at least 40%.
  192.  
  193. 6.3    The maximum degree of isochronous distortion of the send aggregate signals of the 
  194. TDM system shall be 5%.
  195.  
  196. 6.4    When the TDM system is operated over an international telephone-type circuit, a 
  197. modem complying with the appropriate aspects of  the  Series-V  Recommendations  (in
  198. particular Recommendation V.23) should preferably be employed.
  199.  
  200. 7.     Control channel encoding
  201.  
  202. 7.1    The 50 bit/s control channel, the position of which in the frame described in 5 
  203. is accurately known, enables all risk of imitation to be eliminated.
  204.  
  205. 7.2    The structure of the control channel shall be in accordance with Figure 2/R.1xy. 
  206. It corresponds to an anisochronous character with a recurrence of 240 ms, formed from a 
  207.  
  208.  
  209.  
  210.  
  211.  
  212.  
  213.  
  214.  
  215.  
  216.  
  217.  
  218. one unit start element of polarity Z, five information elements and a six unit  stop
  219. element of polarity A.
  220.  
  221.  
  222.  
  223.  
  224.  
  225.  
  226.  
  227.  
  228.  
  229.  
  230.  
  231.  
  232.  
  233.  
  234.  
  235.  
  236.  
  237.                                   FIGURE 2/R.1.xy
  238.                                           
  239.                          Branch-line muldex control channel
  240.  
  241.  
  242. 7.3    The control channel information provides for the transmission of information in 
  243. accordance with Table 2/R.1xy.
  244.  
  245.  
  246.                                    TABLE 2/R.1xy
  247.                                           
  248.                    Information transmitted by the control channel
  249.  
  250.  
  251.  
  252.  
  253.  
  254.  
  255.  
  256.  
  257.  
  258.  
  259.  
  260.  
  261.  
  262.  
  263.  
  264.  
  265.  
  266.  
  267.  
  268.  
  269.  
  270.  
  271.  
  272.  
  273.  
  274.  
  275. Note - The least significant bits are sent first.
  276.  
  277.  
  278. 8.     Synchronizing
  279.  
  280.  
  281.  
  282.  
  283.  
  284.  
  285.  
  286. 8.1    The maximum average synchronization time in the absence of error and imitation 
  287. shall be 600 ms.
  288.  
  289. 8.2    Synchronism shall be considered  achieved  after  recognition  of  the  frame
  290. positioning pattern (sequence of two elements of polarity Z followed by an element of 
  291. polarity A) as described in 5 and at least two successive recognitions of the control 
  292. channel (6 elements of polarity A followed by one element of polarity Z modulo 12) in 
  293. compliance with 7.
  294.  
  295. 8.3    The maximum time loss of sychronization due to a steady polarity signal shall be 
  296. 120 ms.
  297.  
  298. 8.4     The  maximum  time  loss  of  synchronization  for  repeated  error  on  the
  299. synchronization pattern in the control channel shall be 380 ms.
  300.  
  301. 9.     Telex signalling
  302.  
  303. 9.1    Specifications for the signals used to establish, to clear and to control telex 
  304. calls are laid down in Recommendation U.1 (types A and B), U.11 (type  C)  and  U.12
  305. (type D). Recommendation U.25 lists the modes of both-way telex signalling on a single 
  306. circuit and the signalling combinations on a given aggregate that a TDM terminal shall 
  307. be capable of handling.
  308.  
  309. 9.2    Recommendation U.25 also lays down the tolerances on the control signals from a 
  310. TDM terminal to telex and vice versa.
  311.  
  312. 10.    Maintenance
  313.  
  314.        The   branch   looping   facilities   shall   remain   in   accordance   with
  315. Recommendation R.115.
  316.  
  317. 11.    Numbering of channels
  318.  
  319.        The numbering of channels for the branch line telegraph muldex  is  given  in
  320. Tables 1/R.114 and 4/R.114  in  accordance  with  the  numbering  scheme  concerning
  321. Recommendations R.101 and R.102.
  322.  
  323. 12.    Channel selection
  324.  
  325.        Remote channels shall be grouped so as to provide  maximum  ease  of  use  of
  326. heterogeneous frames, a time slot allocation involving little variation in the sampling 
  327. rate being retained.
  328.  
  329.        The selection of channel grouping and the method used shall be based on bilateral 
  330. agreement, particularly when the channels of an existing system have to be  branched
  331. without there being any possibility of a reconfiguration of the whole.
  332.  
  333.        Tables 3 and 4/R.1xy give an example of remote channel grouping on the basis of 
  334. muldexes in conformity with Recommendation R.101 or R.102.
  335.  
  336.                                    TABLE 3/R.1xy
  337.                                           
  338.              Example of grouping of remote channels for an R.101 muldex
  339.  
  340.  
  341. ─────────────────────────────────────────────────────────────────────────── 
  342.  
  343.  
  344.  
  345.  
  346.  
  347.  
  348.  
  349.  
  350.  
  351.  
  352.  
  353.  
  354.  
  355.  
  356.  
  357.  
  358.  
  359.  
  360.  
  361.  
  362.  
  363.  
  364.  
  365.  
  366.  
  367.  
  368.  
  369.  
  370.  
  371.  
  372.  
  373.  
  374.  
  375.  
  376. 1)     Although incomplete, a sixth remote channel could  be  implemented  with  the
  377.        remaining 50 baud channels.
  378.  
  379. 2)     Channel 0516 may not be remoted when the corresponding TS is used to transmit the 
  380.        maintenance channel in the R.101 multiplexer.
  381.  
  382.  
  383.                                    TABLE 4/R.1xy
  384.                                           
  385.              Example of grouping of remote channels for an R.102 muldex
  386.  
  387.  
  388.  
  389.  
  390.  
  391.  
  392.  
  393.  
  394.  
  395.  
  396.